Atlas Copco XAS 750
Mobile Rig 01 (Class 8 blast truck)
- Capacity
- 750 CFM
- Pressure
- 125 psi
- Drive
- Diesel, Deutz
- Hours
- 4,200
Equipment doesn't make a blast shop good — operators do. But the wrong equipment limits what a good operator can achieve. Below is a working inventory of what we run, organized by category, with the specifications that actually matter on a job.
Nothing on this page is aspirational. Every item is in active service or clearly marked as retired.
Industrial equipment is easy to over-buy. A 1,200 CFM compressor sounds impressive on a website but is wasted on most jobs — you're burning diesel to move air through a nozzle that can only use 400 of it. What actually matters is having the right capacity for the work you do, with enough redundancy that a failure doesn't stop the job.
Our approach is a mix: standard equipment across the fleet so a failure can be swapped out mid-job without retraining operators, plus a few specialized pieces that open up job types most shops can't take. Everything gets serviced on the manufacturer's schedule, not on a "wait until it breaks" schedule.
Blast pots hold the media, pressurize it, and feed it into the airstream through a metering valve. Different sizes exist because different jobs need different media volumes per shift.
Used on 90% of industrial work. Best balance of cut rate and air consumption.
Faster cut on large flat surfaces. Requires a 600+ CFM compressor.
Small parts, intricate geometry, controlled cuts. Lower flow rate.
Reduced pressure for sheet metal. Wide pattern, low impact.
The blast pot is only as good as the air going into it. A compressor too small for the nozzle starves the blast, which produces a weak cut rate, an uneven profile, and frustrated operators. Every compressor below is matched to a specific pot or nozzle size.
Mobile Rig 01 (Class 8 blast truck)
Mobile Rig 04 (marine barge package)
Mobile Rig 02 (blast trailer)
Mobile Rig 03 (dustless containment unit)
Mobile Rig 05 (emergency response)
Mobile Rig 06 (high-reach telescopic)
Shop air — four blast bays
Backup shop compressor
Compressors are serviced on a 250-hour oil-change cycle, 500-hour filter cycle, and annual full service regardless of hours. Hour meters are logged weekly — that's how we catch a failing unit before it fails on a job.
Containment is where industrial blasting and environmental responsibility meet. Spent blast media is a regulated waste stream; containment isn't optional on any job we run.
Heavy poly draped over scaffold frames, sealed at the base. Our standard containment method for field tank and structural work. Reusable after cleaning on multiple jobs.
Modular aluminum-framed panels for jobs requiring a more durable enclosure — long-duration work, tight-access sites, or where shrink-wrap can't hold shape.
Three HEPA H14-rated vacuum units integrated with the blast heads on Rig 03 and available for any job that requires dustless operation. Captures 99.97% of particles above 0.3 microns.
Media is swept or vacuumed into 55-gallon drums or Super Sacks on site. Non-hazardous media is transported on our own truck to a licensed disposal facility. Hazardous media is hauled by a hazmat-certified hauler with a manifest.
The coating line runs parallel to the blast bays, so most parts go straight from blast to coating without a staging delay. This is what makes same-day blast-to-coat possible on most jobs.
Two-station powder booth with corona and tribo guns. Manual application for variable geometry parts, with a recovery system that reclaims overspray.
Gas-fired forced-air walk-in oven with overhead monorail conveyor. Internal envelope 8 ft × 4 ft × 4 ft, max part weight 1,800 lb per hanger. Temperature control ±5°F.
Two enclosed spray bays with downdraft ventilation, explosion-proof lighting, and air-fed respirators. Used for epoxy, urethane, and zinc-rich primer application.
The blast bays and coating line share a covered staging aisle. Parts transfer from blast to primer in minutes, not hours — this is the biggest single factor in reducing flash rust on Houston-area jobs.
Every job we complete ships with a documentation binder. These are the instruments that generate the data that goes into it.
Elcometer 224 digital profile gauge. Reads peak-to-valley profile directly in mils or microns on blasted surfaces. Calibrated annually, checked before every job.
Output / Rz profile reading per panelTestex replica tape for legacy profile checks where a physical record is required. Read with a spring micrometer, tape stored with the job file.
Output / Physical record per spot-checkElcometer 456 dry film thickness gauge, ferrous and non-ferrous modes. Reads 0–60 mil with ±3% accuracy. Used after every coating application.
Output / DFT reading per coated partVaisala SHM40 in-situ relative humidity probes for ASTM F2170 testing on concrete. Holes drilled to 40% of slab thickness, probes left 72+ hours.
Output / % RH reading per test locationChloride testing on blast-cleaned steel. Patch applied to a measured area, injected with distilled water, extracted and titrated for chloride concentration.
Output / µg/cm² chloride readingOlympus 45MG ultrasonic thickness gauge for steel and aluminum. Used to measure remaining wall thickness on corroded assets and panel gauge on automotive work.
Output / Wall thickness reading per locationWet-bulb / dry-bulb psychrometer for on-site environmental conditions. Required for computing dew point at blast time, per most coating specifications.
Output / Ambient & dew point logPosiTest AT adhesion tester for pull-off adhesion testing on existing coatings. Used to determine whether an old coating can be over-coated or must be removed.
Output / psi adhesion strengthEvery mobile rig carries its own air, media, containment, and recovery. The full specifications for each rig are on the mobile blasting page — the summary below shows what's on board.
Or it fails because it was never maintained. Every piece of equipment at this shop runs on a service schedule determined by the manufacturer and logged in a maintenance system. Hour meters are read weekly. Filters and oil get changed before they need to be, not after.
This isn't elaborate or clever — it's just consistent. Blast pots get internal inspection annually for wall thickness. Compressors get oil analysis at 250 hours. Ovens get thermocouple calibration every 6 months. Every rig gets a pre-deployment checklist before it leaves the yard.
If you have a project that requires a specific piece of equipment or capability that isn't listed here, tell us about it. If we don't have it, we usually know who does — and if it's a job worth doing, we'll figure out a way to get it.
Or email [email protected] — we answer within one business day.